Disulfiram Bulk Supply for Industrial Use

China Factory Direct
CAS number 97-77-8
Product name Disulfiram
Stock Stock readily available; annual supply capacity exceeding 1,000 tons.
Grade Agricultural GradePharmaceutical GradeMaterial GradeSpecialty GradeIndustrial GradeReagent Grade
Packaging 25KG/bag500KG/bag1000KG/bag
Sample Test Samples Available (Click to Request Samples)
COA View COA
Price Get Quote
Supply Type Bulk / Contract manufacturing / OEM
Shipping FCL / LCL available
Payment Terms Support FOB \ CIF \ EXW quotations, and accept Letter of Credit (L/C).
Manufacturer Greenrock Chemical(China Factory)
Ordering Procedure & Service Assurance
Inquiry
Inquiry
Submit requirements
Quotation
Quotation
Clear pricing
Spec
Spec Confirmation
Avoid mismatch
Sample
Sample Testing
Verify quality
Order
Order
Secure deal
Delivery
Delivery
On-time
Spec Confirmation
Sample Testing
Contract Protection
QC Inspection
On-time Delivery

QUOTE TYPE

FOB (Free On Board)
CIF (Cost, Insurance, Freight)
EXW (Ex Works)

PACKAGING TYPE

TOTAL QUANTITY(KG)

PREFERRED SHIPPING METHOD

Air Freight
Sea Freight

YOUR COMPANY

YOUR E-MAIL

Calculate Summary

Based on current marketvolatility and material availability.

CAS No:97-77-8
QUOTE TYPE:--
PACKAGING TYPE:--
TOTAL QUANTITY:--
SHIPPING METHOD:--

Documents We Provide for Disulfiram

COA TDS SDS NMR MOA Certificate of Origin Transport Report TSCA Declaration Production Flow Chart
Pre-sale: Only COA, SDS and NMR are available.
Post-sale: Full documentation is provided.
To request documents, please contact us via email at sales@GRchemical.com.
Bulk Disulfiram Supplier from China

17+ years in chemical exports.Fully compliant, reliable supply.Your B2B partner in bulk chemical procurement.

Industrial Applications of Disulfiram

Industry Application Process
Rubber Industry Vulcanization accelerator Used in the vulcanization of natural and synthetic rubber to accelerate crosslinking reactions and improve vulcanization efficiency
Rubber Industry Scorch inhibitor (delay agent) Suppresses premature vulcanization during mixing and processing to enhance processing safety
Rubber Industry Sulfur donor Provides reactive sulfur atoms for crosslinking in sulfur-free or low-sulfur formulations
Polymer Industry Free-radical initiator Initiates monomer polymerization in emulsion or solution polymerization systems
Pesticide Industry Fungicide intermediate Serves as a raw material for synthesizing certain sulfur-containing fungicides or insecticides
Analytical Chemistry Colorimetric reagent Used for colorimetric determination of metal ions such as copper and silver
Pharmaceutical Industry Antiparasitic drug intermediate Acts as a precursor compound in the synthesis of anthelmintic or antifungal drugs

Manufacturing Quality Control of Disulfiram

Test Item Common Test Method Method Overview
Assay (Purity) High-Performance Liquid Chromatography (HPLC) Uses a C18 reversed-phase column with methanol/water or acetonitrile/water as the mobile phase. The TETD peak area is detected by a UV detector (typically at 254 nm), and the assay is calculated using external or internal standard methods. Offers high accuracy and good reproducibility.
Gas Chromatography (GC) Suitable for volatile samples, which may require derivatization. Separation is achieved using a capillary column, with quantification by FID detection. Applicable for residual organic solvents and main component analysis, but caution is needed for thermally unstable substances.
Melting Point Melting Point Apparatus Method Determined according to Chinese Pharmacopoeia or ASTM standards using capillary method or automatic melting point apparatus. The theoretical melting point of TETD is 130–135°C, used for preliminary assessment of purity and crystalline form consistency.
Moisture Content Karl Fischer Titration Based on the quantitative reaction of iodine-sulfur dioxide-pyridine-methanol system with water. Moisture content is determined by potentiometric or coulometric methods. Essential for controlling moisture that affects storage stability (TETD is hygroscopic).
Residue on Ignition (Ash Content) Ignition and Gravimetric Method The sample is ignited at high temperature (500–600°C) until constant weight. The residue is weighed to calculate ash content, used to evaluate levels of inorganic impurities (e.g., metal catalyst residues).
Heavy Metal Content Atomic Absorption Spectroscopy (AAS) or ICP-MS After acid digestion of the sample, AAS or ICP-MS is used to determine concentrations of heavy metals such as lead, cadmium, mercury, and arsenic. Ensures compliance with pharmaceutical or food-grade rubber additive standards (e.g., FDA, REACH).
Residual Solvents Headspace Gas Chromatography (HS-GC) Using headspace sampling technique to detect residual organic solvents (e.g., ethanol, acetone, toluene) from manufacturing processes. Controlled against limits specified in ICH Q3C guidelines to ensure product safety.
Chloride Content Ion Chromatography (IC) or Silver Nitrate Titration After dissolving the sample, chloride ion concentration is measured by ion chromatography, or by titration with silver nitrate standard solution forming AgCl precipitate, with endpoint detection by indicator. Used to control chloride impurities in raw materials.
Sulfur Content Combustion-Iodometric Method or Sulfur Analyzer The sample is combusted at high temperature, converting sulfur to SO₂, which is absorbed and titrated with iodine solution, or directly measured using a dedicated sulfur analyzer. Assesses whether sulfur content matches the theoretical value based on molecular formula (C₈H₁₆N₂S₄).
Appearance and Color Visual Comparison or Colorimeter Sample should appear as white to light yellow crystalline powder, free from visible impurities. A colorimeter (e.g., HunterLab) may be used to quantify yellowness index (YI), ensuring color consistency between batches.
Solubility and pH (aqueous suspension) Solubility Test + pH Meter Sample is suspended in water to observe solubility (TETD is nearly insoluble in water); the supernatant is tested for pH (should be near neutral, pH 6–8), indicating possible acidic/alkaline impurity contamination.
Thermal Stability (DSC/TGA) Differential Scanning Calorimetry (DSC) / Thermogravimetric Analysis (TGA) DSC detects melting endothermic peaks and decomposition temperatures; TGA monitors weight loss curves to assess onset of thermal decomposition (typically >200°C). Used for process control and evaluation of storage conditions.

Technical Specifications of Disulfiram

Test Item Specification
Appearance White to orange to green crystalline powder
Purity >=98.0% (HPLC)
Melting Point 135–142°C
Water Content (KF) <=0.5%
Total Impurities <=2.0%
Single Impurity <=0.5%
Heavy Metals <=10 ppm
Residue on Ignition <=0.1%
Specifications vary by industry. Reach out to our technical experts for a COA tailored specifically to your application. Email:selse@GRchemical.com

Download COA of Disulfiram

CAS/Product ID *Required fields
Lot/Batch Number *Required fields

NMR Spectra of Disulfiram

Safety Information of Disulfiram

Pictograms
Signal Word Warning
Safety Data Sheet

Packaging of Disulfiram

We have a diverse range of chemicals in stock. Available in Bagged goods (25 kg.),Big bags (500 kg.), Big bags (1000 kg.).

Industrial Disulfiram Procurement FAQ

1. How do you ensure product quality consistency?
We rely on a mature China-based manufacturing system and implement strict batch control and quality inspection for every shipment. Our production process complies with ISO 9001 standards, and a COA is provided for each batch to ensure consistent and reliable quality.

2. Do you offer competitive pricing for bulk orders?
Yes, as a China-based manufacturer and bulk supplier, we provide tiered pricing based on order volume. We support FOB and CIF quotations, as well as L/C payment terms for large transactions to meet international trade requirements.

3. Can you support large-volume or long-term supply?
We have stable production capacity and a well-established supply chain, enabling continuous bulk supply. We support ton-level and container-level orders, as well as long-term cooperation projects.

4. What is your typical lead time?
For in-stock products, shipment can be arranged within 1–3 days. For bulk packaging or customized orders, lead time depends on the specific quantity and production schedule.

5. What documents do you provide?
We can provide complete documentation upon request, including COA, SDS, TDS, and other compliance certificates, meeting industrial procurement and export requirements.

6. Can you customize product specifications or packaging?
Yes, we support customization of parameters such as purity, impurities, residual solvents, and heavy metals. We also offer various bulk packaging options, including 25kg bags, drums, and IBC tanks, suitable for industrial applications and transportation.

7. What shipping options do you support?
We support both FCL (Full Container Load) and LCL (Less than Container Load) shipments, and can flexibly arrange logistics solutions based on order size to meet bulk chemical export needs.

8. Do you provide technical or application support?
Yes, we provide basic application guidance and technical support based on industry experience to help customers optimize product usage.

9. How do you handle compliance and export regulations?
We are familiar with international trade and export regulations, ensuring all products comply with relevant requirements. We also provide complete documentation to support smooth customs clearance and global delivery.

Industrial
Use
Bulk
Supply
Factory
Direct
ISO 9001
Certified
Samples
Available
Stable
Supply