China Factory Direct
|
|
| CAS number | 122-69-0 |
| Product name | Cinnamyl cinnamate |
| Stock | Stock readily available; annual supply capacity exceeding 1,000 tons. |
| Grade | Pharmaceutical GradeIndustrial GradeSpecialty GradeCosmetic GradeFood Grade |
| Packaging | 25KG/bag500KG/bag1000KG/bag |
| Sample | Test Samples Available (Click to Request Samples) |
| COA | View COA |
| Price | Get Quote |
| Supply Type | Bulk / Contract manufacturing / OEM |
| Shipping | FCL / LCL available |
| Payment Terms | Support FOB \ CIF \ EXW quotations, and accept Letter of Credit (L/C). |
| Manufacturer | Greenrock Chemical(China Factory) |
Based on current marketvolatility and material availability.
17+ years in chemical exports.Fully compliant, reliable supply.Your B2B partner in bulk chemical procurement.
| Industry | Application | Process |
|---|---|---|
| Food | Food additive (flavoring agent, seasoning) | Synthesis or natural extraction |
| Cosmetics | Fragrance ingredient (perfumes, skincare products, soaps) | Esterification |
| Pharmaceuticals | Pharmaceutical excipient (controlled-release agent, solubilizer) | Chemical synthesis |
| Tobacco | Tobacco flavoring (odor enhancement) | Blending and formulation |
| Household products | Fragrance component in detergents and air fresheners | Compounding |
| Chemicals | Organic synthesis intermediate (for production of other ester compounds) | Catalytic reaction |
| Test Item | Common Testing Methods | Method Overview |
|---|---|---|
| Appearance | Visual Inspection | Observe the sample's color, state, and clarity under natural light or standard lighting to determine the presence of impurities or precipitates. |
| Chromatographic Purity | Gas Chromatography (GC) | Utilize capillary column gas chromatography for qualitative analysis based on retention time; calculate the content of the main component and total impurities using peak area normalization. |
| Assay | Gas Chromatography (GC) or High-Performance Liquid Chromatography (HPLC) | GC is commonly used for volatile esters; HPLC is suitable for thermally unstable samples. Quantification of cinnamyl cinnamate is performed using external or internal standard methods. |
| Refractive Index (20°C) | Refractometry | Measure the refractive index of the sample at a specified temperature using an Abbe refractometer for identification and auxiliary purity assessment. |
| Relative Density | Density bottle method or electronic densitometer | Determine the mass per unit volume and compare with standard values to evaluate purity and consistency. |
| Acid Value | Acid-base Titration | Titrate free acids in the sample with a standardized potassium hydroxide (KOH) ethanol solution; calculate the milligrams of KOH consumed per gram of sample. |
| Ester Value | Reflux Saponification-Titration Method | Reflux the sample with excess KOH ethanol solution to saponify esters; titrate the residual alkali with standardized acid to calculate the amount of alkali required for ester hydrolysis. |
| Peroxide Value | Iodometric Titration | Peroxides in the sample oxidize potassium iodide to liberate iodine, which is then titrated with standardized sodium thiosulfate solution to determine the degree of peroxidation. |
| Water Content | Karl Fischer Titration | Quantitatively determine trace water in the sample using an electrochemical reaction; suitable for organic compounds with low moisture content. |
| Heavy Metals | Colorimetric Methods (e.g., lead and arsenic limit tests) | Employ sulfide colorimetry or atomic absorption spectroscopy (AAS) to detect residual heavy metals such as lead and arsenic. |
| Residual Solvents | Gas Chromatography (GC) | According to ICH guidelines, detect organic solvents potentially residual from manufacturing processes (e.g., methanol, benzene, chloroform). |
| Ultraviolet Absorption (UV) | UV-Visible Spectrophotometry | Measure absorbance at specific wavelengths (e.g., 254 nm, 280 nm) to assess conjugated structure impurities or degradation products. |
| Melting Point / Freezing Point | Capillary Method or Automatic Melting Point Apparatus | Determine the temperature at which the substance transitions from solid to liquid; used for identification and purity assessment (if applicable). |
| Test Item | Specification |
|---|---|
| Appearance | Off-white solid |
| Purity | >=98.0% |
| Water Content (KF) | <=0.5% |
| Total Impurities | <=2.0% |
| Single Impurity | <=0.5% |
| Melting Point | 48–52°C |
| Refractive Index (n20/D) | 1.478–1.482 |
| Odor | Characteristic floral odor |
|
|
|
| CAS/Product ID | *Required fields | |
| Lot/Batch Number | *Required fields | |
1. How do you ensure product quality consistency?
We rely on a mature China-based manufacturing system and implement strict batch control and quality inspection for every shipment. Our production process complies with ISO 9001 standards, and a COA is provided for each batch to ensure consistent and reliable quality.
2. Do you offer competitive pricing for bulk orders?
Yes, as a China-based manufacturer and bulk supplier, we provide tiered pricing based on order volume. We support FOB and CIF quotations, as well as L/C payment terms for large transactions to meet international trade requirements.
3. Can you support large-volume or long-term supply?
We have stable production capacity and a well-established supply chain, enabling continuous bulk supply. We support ton-level and container-level orders, as well as long-term cooperation projects.
4. What is your typical lead time?
For in-stock products, shipment can be arranged within 1–3 days. For bulk packaging or customized orders, lead time depends on the specific quantity and production schedule.
5. What documents do you provide?
We can provide complete documentation upon request, including COA, SDS, TDS, and other compliance certificates, meeting industrial procurement and export requirements.
6. Can you customize product specifications or packaging?
Yes, we support customization of parameters such as purity, impurities, residual solvents, and heavy metals. We also offer various bulk packaging options, including 25kg bags, drums, and IBC tanks, suitable for industrial applications and transportation.
7. What shipping options do you support?
We support both FCL (Full Container Load) and LCL (Less than Container Load) shipments, and can flexibly arrange logistics solutions based on order size to meet bulk chemical export needs.
8. Do you provide technical or application support?
Yes, we provide basic application guidance and technical support based on industry experience to help customers optimize product usage.
9. How do you handle compliance and export regulations?
We are familiar with international trade and export regulations, ensuring all products comply with relevant requirements. We also provide complete documentation to support smooth customs clearance and global delivery.