China Factory Direct
|
|
| CAS number | 141196-64-7 |
| Product name | DL-2-(2-Chlorophenyl)glycine |
| Stock | Stock readily available; annual supply capacity exceeding 1,000 tons. |
| Grade | Agricultural GradeIndustrial GradeSpecialty Grade |
| Packaging | 25KG/bag500KG/bag1000KG/bag |
| Sample | Test Samples Available (Click to Request Samples) |
| COA | View COA |
| Price | Get Quote |
| Supply Type | Bulk / Contract manufacturing / OEM |
| Shipping | FCL / LCL available |
| Payment Terms | Support FOB \ CIF \ EXW quotations, and accept Letter of Credit (L/C). |
| Manufacturer | Greenrock Chemical(China Factory) |
Based on current marketvolatility and material availability.
17+ years in chemical exports.Fully compliant, reliable supply.Your B2B partner in bulk chemical procurement.
| Industry | Application | Process |
|---|---|---|
| Pharmaceutical Intermediates | Key chiral intermediate for the synthesis of the antibiotic levofloxacin | L-isomer obtained via chiral resolution or asymmetric synthesis, then used in cyclization and fluorination steps to construct the quinolone core |
| Agrochemical Intermediates | Structural building block for novel herbicides and fungicides | Chlorinated aryl glycine derivative employed in amidation and cyclization reactions to assemble the active molecular scaffold |
| Organic Synthesis | Precursor for chiral ligands and functional materials | Specific functional groups introduced via esterification, reduction, or coupling reactions for catalyst design or polymer monomer synthesis |
| Test Item | Common Testing Methods | Method Overview |
|---|---|---|
| Content Assay | High-Performance Liquid Chromatography (HPLC) | Utilizes a reversed-phase C18 column with a mobile phase such as phosphate buffer-methanol, detected by a UV detector (e.g., 210 nm or 254 nm). Quantification is performed using external or internal standard methods. Suitable for determining purity and active ingredient content. |
| Chiral Purity (Enantiomeric Ratio) | Chiral High-Performance Liquid Chromatography (Chiral HPLC) | Employs chiral stationary phase columns (e.g., Chiralpak AD-H, AS-H, etc.) under normal-phase or polar organic conditions to separate D- and L-isomers, evaluating enantiomeric excess (ee value) to control optical purity. |
| Related Substances (Impurities) | High-Performance Liquid Chromatography (HPLC) | Uses gradient elution to enhance separation capability, detecting possible synthetic intermediates, by-products, or degradation products in the active pharmaceutical ingredient. Impurity peak areas are calculated and controlled within specified limits. |
| Melting Point | Capillary Melting Point Determination | Sample is loaded into a capillary tube and heated gradually in a melting point apparatus; the initial and complete melting temperatures are observed. DL-o-chlorophenylglycine typically exhibits a specific melting range, used for preliminary identification and purity assessment. |
| Water Content | Karl Fischer Titration | Determines water content in samples using a Karl Fischer titrator, available in volumetric or coulometric modes, suitable for controlling moisture loss and process stability. |
| Loss on Drying | Thermogravimetric Analysis (TGA) or Oven Drying Method | Sample is dried at a specified temperature (e.g., 105°C) until constant weight is achieved; percentage weight loss is calculated to reflect crystalline water or residual solvents. |
| Residue on Ignition (Sulfated Ash) | Gravimetric Method | Sample is treated with sulfuric acid and then incinerated at high temperature; the mass of residual inorganic material is weighed to control inorganic impurities. |
| Heavy Metals | Sulfide Colorimetric Method (Chinese Pharmacopoeia Method) | In acidic conditions, reacts with hydrogen sulfide or thioacetamide to form colored precipitates; colorimetric determination of total heavy metals such as lead. |
| Solution Clarity and Color | Visual Color Comparison / Turbidity Method | Sample is dissolved in a specified solvent (e.g., water or ethanol) and compared visually with standard color or turbidity reference solutions to assess solution appearance quality. |
| Structure Confirmation | Infrared Spectroscopy (IR), Nuclear Magnetic Resonance (NMR), Mass Spectrometry (MS) | IR identifies functional groups; ¹H-NMR and ¹³C-NMR confirm molecular structure; MS provides molecular ion peaks and fragmentation patterns, used collectively for structural confirmation. |
| Test Item | Specification |
|---|---|
| Appearance | White crystalline solid |
| Purity | >=98.0% (HPLC) |
| Water Content (KF) | <=0.5% |
| Melting Point | 148–152°C |
| Total Impurities | <=2.0% |
| Single Impurity | <=0.5% |
| Heavy Metals | <=10 ppm |
| Residue on Ignition | <=0.1% |
|
|
|
| CAS/Product ID | *Required fields | |
| Lot/Batch Number | *Required fields | |
1. How do you ensure product quality consistency?
We rely on a mature China-based manufacturing system and implement strict batch control and quality inspection for every shipment. Our production process complies with ISO 9001 standards, and a COA is provided for each batch to ensure consistent and reliable quality.
2. Do you offer competitive pricing for bulk orders?
Yes, as a China-based manufacturer and bulk supplier, we provide tiered pricing based on order volume. We support FOB and CIF quotations, as well as L/C payment terms for large transactions to meet international trade requirements.
3. Can you support large-volume or long-term supply?
We have stable production capacity and a well-established supply chain, enabling continuous bulk supply. We support ton-level and container-level orders, as well as long-term cooperation projects.
4. What is your typical lead time?
For in-stock products, shipment can be arranged within 1–3 days. For bulk packaging or customized orders, lead time depends on the specific quantity and production schedule.
5. What documents do you provide?
We can provide complete documentation upon request, including COA, SDS, TDS, and other compliance certificates, meeting industrial procurement and export requirements.
6. Can you customize product specifications or packaging?
Yes, we support customization of parameters such as purity, impurities, residual solvents, and heavy metals. We also offer various bulk packaging options, including 25kg bags, drums, and IBC tanks, suitable for industrial applications and transportation.
7. What shipping options do you support?
We support both FCL (Full Container Load) and LCL (Less than Container Load) shipments, and can flexibly arrange logistics solutions based on order size to meet bulk chemical export needs.
8. Do you provide technical or application support?
Yes, we provide basic application guidance and technical support based on industry experience to help customers optimize product usage.
9. How do you handle compliance and export regulations?
We are familiar with international trade and export regulations, ensuring all products comply with relevant requirements. We also provide complete documentation to support smooth customs clearance and global delivery.