Phosphonomycin (R)-1-phenethylamine salt Bulk Supply for Industrial Use

China Factory Direct
CAS number 25383-07-7
Product name Phosphonomycin (R)-1-phenethylamine salt
Stock Stock readily available; annual supply capacity exceeding 1,000 tons.
Grade Industrial Grade
Packaging 25L/drum200L/drum1000L/IBC
Sample Test Samples Available (Click to Request Samples)
COA View COA
Price Get Quote
Supply Type Bulk / Contract manufacturing / OEM
Shipping FCL / LCL available
Payment Terms Support FOB \ CIF \ EXW quotations, and accept Letter of Credit (L/C).
Manufacturer Greenrock Chemical(China Factory)
Ordering Procedure & Service Assurance
Inquiry
Inquiry
Submit requirements
Quotation
Quotation
Clear pricing
Spec
Spec Confirmation
Avoid mismatch
Sample
Sample Testing
Verify quality
Order
Order
Secure deal
Delivery
Delivery
On-time
Spec Confirmation
Sample Testing
Contract Protection
QC Inspection
On-time Delivery

QUOTE TYPE

FOB (Free On Board)
CIF (Cost, Insurance, Freight)
EXW (Ex Works)

PACKAGING TYPE

TOTAL QUANTITY(KG)

PREFERRED SHIPPING METHOD

Air Freight
Sea Freight

YOUR COMPANY

YOUR E-MAIL

Calculate Summary

Based on current marketvolatility and material availability.

CAS No:25383-07-7
QUOTE TYPE:--
PACKAGING TYPE:--
TOTAL QUANTITY:--
SHIPPING METHOD:--

Documents We Provide for Phosphonomycin (R)-1-phenethylamine salt

COA TDS SDS NMR MOA Certificate of Origin Transport Report TSCA Declaration Production Flow Chart
Pre-sale: Only COA, SDS and NMR are available.
Post-sale: Full documentation is provided.
To request documents, please contact us via email at sales@GRchemical.com.
Bulk Phosphonomycin (R)-1-phenethylamine salt Supplier from China

17+ years in chemical exports.Fully compliant, reliable supply.Your B2B partner in bulk chemical procurement.

Industrial Applications of Phosphonomycin (R)-1-phenethylamine salt

Industry Application Process
Pharmaceuticals Chiral intermediates Phosphomycin is reacted with (R)-1-phenylethylamine in a polar solvent to form a salt, followed by recrystallization to obtain phosphomycin (R)-1-phenylethylamine salt with high optical purity for subsequent antibiotic synthesis

Manufacturing Quality Control of Phosphonomycin (R)-1-phenethylamine salt

Test Item Common Testing Methods Method Overview
Identification Infrared Spectroscopy (IR) Determine the infrared absorption spectrum of the sample and compare it with standard reference spectra to confirm functional group characteristics and structural consistency.
Proton Nuclear Magnetic Resonance (¹H NMR) Analyze chemical shifts, coupling constants, and other parameters of hydrogen atoms using nuclear magnetic resonance technology to verify the molecular structure of the target compound.
Content Determination High-Performance Liquid Chromatography (HPLC) Use reversed-phase HPLC with a C18 column and ultraviolet detector (typically around 210 nm) for quantitative determination of the main component.
Related Substances (Impurities) High-Performance Liquid Chromatography (HPLC) Employ gradient or isocratic elution programs to separate and detect potential organic impurities (e.g., epimeric forms of fosfomycin, degradation products, etc.).
Specific Rotation Polarimetry Measure the optical rotation of the solution under specified wavelength (usually sodium D line, 589 nm) and temperature, then calculate specific rotation to assess chiral purity.
pH Value pH Meter Measurement Dissolve the sample in water at a defined concentration and measure its acidity or alkalinity using a calibrated pH meter.
Loss on Drying Thermogravimetric Analysis (TGA) or Atmospheric Drying Method Dry the sample at a specified temperature (e.g., 105°C) until constant weight, then calculate the percentage loss due to moisture and other volatile components.
Residue on Ignition / Ash Content Residue on Ignition Test Method Ignite the sample at high temperature (approximately 700–800°C), then weigh the remaining inorganic residue to evaluate the content of inorganic impurities.
Residual Solvents Gas Chromatography (GC) Detect trace organic solvents (e.g., methanol, acetone) potentially left over from synthesis or purification processes using headspace or direct injection GC.
Heavy Metals Atomic Absorption Spectroscopy (AAS) or ICP-MS Determine residual levels of heavy metals such as lead, arsenic, cadmium, and mercury using atomic absorption spectroscopy or inductively coupled plasma mass spectrometry.
Microbial Limits Microbial Limit Test (Pharmacopoeial Methods) Test for total aerobic bacteria, mold/yeast count, and control organisms (e.g., Escherichia coli) according to standards set forth in the Chinese Pharmacopoeia or USP.
Water Content Karl Fischer Titration Specifically determine water content in the sample; suitable for compounds containing crystalline water or those prone to moisture absorption.

Technical Specifications of Phosphonomycin (R)-1-phenethylamine salt

Test Item Specification
Appearance White to off-white crystalline powder
Purity >=98.5%
Water Content (KF) <=0.5%
Melting Point 142-146°C
Optical Rotation +22.0 to +24.0° (c=1, in methanol)
Total Impurities <=1.5%
Single Impurity <=0.5%
Heavy Metals <=10 ppm
Specifications vary by industry. Reach out to our technical experts for a COA tailored specifically to your application. Email:selse@GRchemical.com

Download COA of Phosphonomycin (R)-1-phenethylamine salt

CAS/Product ID *Required fields
Lot/Batch Number *Required fields

NMR Spectra of Phosphonomycin (R)-1-phenethylamine salt

Safety Information of Phosphonomycin (R)-1-phenethylamine salt

Pictograms
Signal Word Warning
Safety Data Sheet

Packaging of Phosphonomycin (R)-1-phenethylamine salt

We have a diverse range of chemicals in stock. Available in IBC (1000 ltr.), Drums (200 ltr.),Drums (25 ltr.).

Industrial Phosphonomycin (R)-1-phenethylamine salt Procurement FAQ

1. How do you ensure product quality consistency?
We rely on a mature China-based manufacturing system and implement strict batch control and quality inspection for every shipment. Our production process complies with ISO 9001 standards, and a COA is provided for each batch to ensure consistent and reliable quality.

2. Do you offer competitive pricing for bulk orders?
Yes, as a China-based manufacturer and bulk supplier, we provide tiered pricing based on order volume. We support FOB and CIF quotations, as well as L/C payment terms for large transactions to meet international trade requirements.

3. Can you support large-volume or long-term supply?
We have stable production capacity and a well-established supply chain, enabling continuous bulk supply. We support ton-level and container-level orders, as well as long-term cooperation projects.

4. What is your typical lead time?
For in-stock products, shipment can be arranged within 1–3 days. For bulk packaging or customized orders, lead time depends on the specific quantity and production schedule.

5. What documents do you provide?
We can provide complete documentation upon request, including COA, SDS, TDS, and other compliance certificates, meeting industrial procurement and export requirements.

6. Can you customize product specifications or packaging?
Yes, we support customization of parameters such as purity, impurities, residual solvents, and heavy metals. We also offer various bulk packaging options, including 25kg bags, drums, and IBC tanks, suitable for industrial applications and transportation.

7. What shipping options do you support?
We support both FCL (Full Container Load) and LCL (Less than Container Load) shipments, and can flexibly arrange logistics solutions based on order size to meet bulk chemical export needs.

8. Do you provide technical or application support?
Yes, we provide basic application guidance and technical support based on industry experience to help customers optimize product usage.

9. How do you handle compliance and export regulations?
We are familiar with international trade and export regulations, ensuring all products comply with relevant requirements. We also provide complete documentation to support smooth customs clearance and global delivery.

Industrial
Use
Bulk
Supply
Factory
Direct
ISO 9001
Certified
Samples
Available
Stable
Supply