1H-Pyrazolo[3,4-b]pyridine-3-carboximidamide, 1-[(2-fluorophenyl)methyl]-, hydrochloride (1:1) Bulk Supply for Industrial Use

China Factory Direct
CAS number 256499-19-1
Product name 1H-Pyrazolo[3,4-b]pyridine-3-carboximidamide, 1-[(2-fluorophenyl)methyl]-, hydrochloride (1:1)
Stock Stock readily available; annual supply capacity exceeding 1,000 tons.
Grade Pharmaceutical Grade
Packaging 25KG/bag
Sample Test Samples Available (Click to Request Samples)
COA View COA
Price Get Quote
Supply Type Bulk / Contract manufacturing / OEM
Shipping FCL / LCL available
Payment Terms Support FOB \ CIF \ EXW quotations, and accept Letter of Credit (L/C).
Manufacturer Greenrock Chemical(China Factory)
Ordering Procedure & Service Assurance
Inquiry
Inquiry
Submit requirements
Quotation
Quotation
Clear pricing
Spec
Spec Confirmation
Avoid mismatch
Sample
Sample Testing
Verify quality
Order
Order
Secure deal
Delivery
Delivery
On-time
Spec Confirmation
Sample Testing
Contract Protection
QC Inspection
On-time Delivery

QUOTE TYPE

FOB (Free On Board)
CIF (Cost, Insurance, Freight)
EXW (Ex Works)

PACKAGING TYPE

TOTAL QUANTITY(KG)

PREFERRED SHIPPING METHOD

Air Freight
Sea Freight

YOUR COMPANY

YOUR E-MAIL

Calculate Summary

Based on current marketvolatility and material availability.

CAS No:256499-19-1
QUOTE TYPE:--
PACKAGING TYPE:--
TOTAL QUANTITY:--
SHIPPING METHOD:--

Documents We Provide for 256499-19-1

COA TDS SDS NMR MOA Certificate of Origin Transport Report TSCA Declaration Production Flow Chart
Pre-sale: Only COA, SDS and NMR are available.
Post-sale: Full documentation is provided.
To request documents, please contact us via email at sales@GRchemical.com.
Bulk 256499-19-1 Supplier from China

17+ years in chemical exports.Fully compliant, reliable supply.Your B2B partner in bulk chemical procurement.

Industrial Applications of 256499-19-1

Industry Application Process
Pharmaceutical R&D Used as an intermediate in the synthesis of JAK kinase inhibitors (e.g., tofacitinib) Multi-step organic synthesis involving condensation, cyclization, and salt formation
Pharmaceutical Manufacturing Used to prepare active pharmaceutical ingredients (APIs) for anti-inflammatory and immunomodulatory drugs Catalytic hydrogenation, nucleophilic substitution, and hydrochloride salt crystallization for purification
Biochemical Research Used as a lead compound or probe molecule in kinase target studies High-throughput screening coupled with structure-based synthetic route optimization

Manufacturing Quality Control of 256499-19-1

Test Item Commonly Used Testing Methods Method Overview
Appearance Visual Inspection Observe the color, physical state, presence of caking, and visible foreign matter under natural or standard lighting conditions.
Identification Infrared Spectroscopy (IR) Compare the sample spectrum with the reference spectrum to confirm consistency of characteristic functional group absorption peaks (e.g., N-H, C=N, C-F, etc.).
Nuclear Magnetic Resonance Spectroscopy (¹H-NMR, ¹⁹F-NMR) Analyze the chemical shifts and coupling constants of hydrogen and fluorine atoms in the molecular structure to verify structural correctness.
Mass Spectrometry (MS or HRMS) Determine molecular ion peaks ([M+H]+ or [M]⁺), confirm molecular weight and fragment ions to verify the compound's structure.
Purity/Content Determination High-Performance Liquid Chromatography (HPLC) Use a reversed-phase C18 column and UV detector (typically at 254 nm or selected based on maximum absorption wavelength). Calculate the purity of the main peak using external standard method or area normalization method.
Water Content Karl Fischer Titration Suitable for determining trace amounts of water in solid samples, using either volumetric or coulometric methods to accurately measure both free and bound water.
Residual Solvents Gas Chromatography (GC) Detect organic solvents possibly residual from the manufacturing process (e.g., methanol, ethanol, dichloromethane, DMF, etc.) in accordance with ICH Q3C guidelines, using appropriate detectors (FID).
Related Substances (Impurities) HPLC with Gradient Elution Detect process impurities and degradation products. Evaluate individual impurity peaks using reference standards or relative response factors to ensure total impurities meet specified limits.
Melting Point Capillary Melting Point Method Determine the temperature range at which the compound transitions from solid to liquid using a melting point apparatus, used for preliminary assessment of purity and material characteristics.
Solution Clarity and Color Visual Color Comparison Prepare a solution of specified concentration and compare its clarity and color with standard color solutions to assess whether it is clear and colorless or within acceptable limits.
Chlorides (for Hydrochloride salts) Ion Chromatography or Argentometric Method Quantitatively determine chloride ion content in hydrochloride salts to verify the salt formation ratio and control inorganic impurities.
Heavy Metals Inductively Coupled Plasma Mass Spectrometry (ICP-MS) or Thioacetamide Method Detect residual toxic elements such as lead, cadmium, mercury, and arsenic, ensuring compliance with pharmacopoeia or ICH Q3D elemental impurity limits.
Sulfated Ash (Residue on Ignition) Gravimetric Analysis Weigh the residue after high-temperature ignition of the sample to assess the content of inorganic impurities.
Microbial Limits Microbial Limit Testing Perform tests for total aerobic microbial count, total combined molds and yeasts count, and specified microorganisms (e.g., Escherichia coli) as per pharmacopoeia requirements. Applicable for non-sterile active pharmaceutical ingredients.

Technical Specifications of 256499-19-1

Test Item Specification
Appearance White solid
Purity >=98.0%
Total Impurities <=2.0%
Single Impurity <=0.5%
Water Content (KF) <=0.5%
Melting Point 195–199 °C
Identification (NMR) Consistent with structure
Residue on Ignition <=0.1%
Heavy Metals <=20 ppm
Specifications vary by industry. Reach out to our technical experts for a COA tailored specifically to your application. Email:selse@GRchemical.com

Download COA of 256499-19-1

CAS/Product ID *Required fields
Lot/Batch Number *Required fields

NMR Spectra of 256499-19-1

Safety Information of 256499-19-1

Pictograms
Signal Word Warning
Safety Data Sheet

Packaging of 256499-19-1

We have a diverse range of chemicals in stock. Available in Bagged goods (25 kg.),Big bags (500 kg.), Big bags (1000 kg.).

Industrial 256499-19-1 Procurement FAQ

1. How do you ensure product quality consistency?
We rely on a mature China-based manufacturing system and implement strict batch control and quality inspection for every shipment. Our production process complies with ISO 9001 standards, and a COA is provided for each batch to ensure consistent and reliable quality.

2. Do you offer competitive pricing for bulk orders?
Yes, as a China-based manufacturer and bulk supplier, we provide tiered pricing based on order volume. We support FOB and CIF quotations, as well as L/C payment terms for large transactions to meet international trade requirements.

3. Can you support large-volume or long-term supply?
We have stable production capacity and a well-established supply chain, enabling continuous bulk supply. We support ton-level and container-level orders, as well as long-term cooperation projects.

4. What is your typical lead time?
For in-stock products, shipment can be arranged within 1–3 days. For bulk packaging or customized orders, lead time depends on the specific quantity and production schedule.

5. What documents do you provide?
We can provide complete documentation upon request, including COA, SDS, TDS, and other compliance certificates, meeting industrial procurement and export requirements.

6. Can you customize product specifications or packaging?
Yes, we support customization of parameters such as purity, impurities, residual solvents, and heavy metals. We also offer various bulk packaging options, including 25kg bags, drums, and IBC tanks, suitable for industrial applications and transportation.

7. What shipping options do you support?
We support both FCL (Full Container Load) and LCL (Less than Container Load) shipments, and can flexibly arrange logistics solutions based on order size to meet bulk chemical export needs.

8. Do you provide technical or application support?
Yes, we provide basic application guidance and technical support based on industry experience to help customers optimize product usage.

9. How do you handle compliance and export regulations?
We are familiar with international trade and export regulations, ensuring all products comply with relevant requirements. We also provide complete documentation to support smooth customs clearance and global delivery.

Industrial
Use
Bulk
Supply
Factory
Direct
ISO 9001
Certified
Samples
Available
Stable
Supply