China Factory Direct
|
|
| CAS number | 3230-94-2 |
| Product name | L-Ornithine L-aspartate salt |
| Stock | Stock readily available; annual supply capacity exceeding 1,000 tons. |
| Grade | Pharmaceutical GradeFood Grade |
| Packaging | 25KG/bag500KG/bag1000KG/bag |
| Sample | Test Samples Available (Click to Request Samples) |
| COA | View COA |
| Price | Get Quote |
| Supply Type | Bulk / Contract manufacturing / OEM |
| Shipping | FCL / LCL available |
| Payment Terms | Support FOB \ CIF \ EXW quotations, and accept Letter of Credit (L/C). |
| Manufacturer | Greenrock Chemical(China Factory) |
Based on current marketvolatility and material availability.
17+ years in chemical exports.Fully compliant, reliable supply.Your B2B partner in bulk chemical procurement.
| Industry | Application | Process |
|---|---|---|
| Pharmaceuticals | Hepatic disease therapeutics | Used as an ammonia detoxifying agent in the urea cycle to reduce blood ammonia levels |
| Pharmaceuticals | Nutritional supplements | Applied to alleviate fatigue, enhance physical stamina, and support muscle growth |
| Food Industry | Functional food additives | Added as an amino acid supplement to enhance product nutritional value |
| Biochemical Research | Amino acid metabolism studies | Used to investigate the urea cycle, amino acid transport, and metabolic mechanisms |
| Sports Nutrition | Sports nutrition supplements | Applied to accelerate muscle recovery, improve endurance, and enhance athletic performance |
| Veterinary Medicine | Animal health products | Applied to support hepatic function and maintain amino acid balance in animals |
| Test Item | Common Testing Methods | Method Overview |
|---|---|---|
| Content Assay (Main Component Analysis) | High-Performance Liquid Chromatography (HPLC) | Utilizes a reversed-phase C18 column with a mobile phase consisting of phosphate buffer and organic solvents (e.g., methanol or acetonitrile). Detection is performed using a UV detector (typically 200–220 nm) to measure the peak areas of L-ornithine and L-aspartic acid. Quantification is carried out via external or internal standard methods to ensure the purity of the main component complies with pharmacopoeial requirements. |
| Purity Analysis | Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) | Combines liquid chromatography with tandem mass spectrometry to precisely identify molecular weight and structural characteristics, enabling confirmation of the target compound and detection of trace impurities (e.g., isomers, degradation products). This is a high-sensitivity and high-specificity method for purity assessment. |
| Amino Acid Composition Analysis | Amino Acid Analyzer (Ion-Exchange Chromatography or Post-derivatization HPLC) | After acid hydrolysis of the sample, amino acids are separated via ion-exchange chromatography or following derivatization (e.g., with DNP or PITC), then quantified using standard amino acid reference substances. This verifies whether the molar ratio of ornithine to aspartic acid conforms to the specified ratio (typically 1:1). |
| Impurity Detection (Related Substances) | HPLC (Main Component Self-Control Method) | HPLC is used to detect potential impurities (e.g., unreacted starting materials, by-products, oxidation products). Impurity limits are set (e.g., ≤0.5%) to monitor product stability and the reliability of the synthetic process. |
| Residual Solvent Detection | Gas Chromatography (GC) | Residual organic solvents (e.g., ethanol, acetone, dichloromethane) potentially present during synthesis are detected using headspace or solution injection methods. Risk assessment is performed in accordance with ICH Q3A/B guidelines to ensure compliance with safety limits. |
| Microbial Limit Test | Microbial Enumeration (Aerobic Bacteria, Mold/Yeast) | Uses culture-based methods to detect microbial contamination in the sample, applicable to non-sterile formulations, ensuring compliance with microbial limit standards specified in the Chinese Pharmacopoeia. |
| Heavy Metal Detection | Atomic Absorption Spectroscopy (AAS) or Inductively Coupled Plasma Mass Spectrometry (ICP-MS) | Following sample digestion, the content of heavy metals such as lead, cadmium, mercury, and arsenic is measured to ensure they remain below pharmacopoeial limits (e.g., lead ≤10 ppm), guaranteeing safety. |
| Appearance and Physical Properties | Visual Inspection + Physical Property Measurement | Visual assessment of powder color, morphology, and odor, along with measurement of physical parameters such as melting point, specific rotation, and pH, serve as preliminary quality indicators. |
| Water Content Determination | Karl Fischer Titration | Uses coulometric or volumetric Karl Fischer titration to precisely determine water content in the sample, preventing moisture absorption that could compromise stability or formulation performance. |
| Test Item | Specification |
|---|---|
| Appearance | White solid |
| Purity | >=98.0% |
| Water Content (KF) | <=0.5% |
| Total Impurities | <=2.0% |
| Single Impurity | <=0.5% |
| Optical Rotation | +26.0 to +29.0 deg (c=1, H2O) |
| Heavy Metals | <=20 ppm |
| Residue on Ignition | <=0.1% |
|
|
|
| CAS/Product ID | *Required fields | |
| Lot/Batch Number | *Required fields | |
1. How do you ensure product quality consistency?
We rely on a mature China-based manufacturing system and implement strict batch control and quality inspection for every shipment. Our production process complies with ISO 9001 standards, and a COA is provided for each batch to ensure consistent and reliable quality.
2. Do you offer competitive pricing for bulk orders?
Yes, as a China-based manufacturer and bulk supplier, we provide tiered pricing based on order volume. We support FOB and CIF quotations, as well as L/C payment terms for large transactions to meet international trade requirements.
3. Can you support large-volume or long-term supply?
We have stable production capacity and a well-established supply chain, enabling continuous bulk supply. We support ton-level and container-level orders, as well as long-term cooperation projects.
4. What is your typical lead time?
For in-stock products, shipment can be arranged within 1–3 days. For bulk packaging or customized orders, lead time depends on the specific quantity and production schedule.
5. What documents do you provide?
We can provide complete documentation upon request, including COA, SDS, TDS, and other compliance certificates, meeting industrial procurement and export requirements.
6. Can you customize product specifications or packaging?
Yes, we support customization of parameters such as purity, impurities, residual solvents, and heavy metals. We also offer various bulk packaging options, including 25kg bags, drums, and IBC tanks, suitable for industrial applications and transportation.
7. What shipping options do you support?
We support both FCL (Full Container Load) and LCL (Less than Container Load) shipments, and can flexibly arrange logistics solutions based on order size to meet bulk chemical export needs.
8. Do you provide technical or application support?
Yes, we provide basic application guidance and technical support based on industry experience to help customers optimize product usage.
9. How do you handle compliance and export regulations?
We are familiar with international trade and export regulations, ensuring all products comply with relevant requirements. We also provide complete documentation to support smooth customs clearance and global delivery.