China Factory Direct
|
|
| CAS number | 402-54-0 |
| Product name | 4-Nitrobenzotrifluoride |
| Stock | Stock readily available; annual supply capacity exceeding 1,000 tons. |
| Grade | Agricultural GradeMaterial GradeSpecialty GradeIndustrial GradeElectronic Grade |
| Packaging | 25KG/bag |
| Sample | Test Samples Available (Click to Request Samples) |
| COA | View COA |
| Price | Get Quote |
| Supply Type | Bulk / Contract manufacturing / OEM |
| Shipping | FCL / LCL available |
| Payment Terms | Support FOB \ CIF \ EXW quotations, and accept Letter of Credit (L/C). |
| Manufacturer | Greenrock Chemical(China Factory) |
Based on current marketvolatility and material availability.
17+ years in chemical exports.Fully compliant, reliable supply.Your B2B partner in bulk chemical procurement.
| Industry | Application | Process |
|---|---|---|
| Pharmaceuticals | Used as an intermediate in the synthesis of antibacterial and antitumor agents | Organic synthesis reactions, including nitration, reduction, and condensation |
| Agrochemicals | Serves as a precursor in the synthesis of herbicides and insecticides | Chemical transformations, including catalytic hydrogenation and nucleophilic substitution |
| Dyes | Used in the preparation of azo dyes and disperse dyes | Dye synthesis processes, including diazotization and coupling |
| Materials | Used in the synthesis of fluorinated functional materials (e.g., liquid crystals, polymer monomers) | Functionalization reactions, including fluorination and polymerization |
| Electronic Chemicals | Used as an intermediate in photoresists or electronic-grade chemicals | Fine chemical processes, including purification and derivatization |
| Detection Item | Common Testing Methods | Method Overview |
|---|---|---|
| Purity Analysis | Gas Chromatography (GC) | Separation using a capillary column and quantification with an FID detector. Purity of the main component is determined by area normalization or external standard method. Suitable for volatile organic compounds, offering high sensitivity and good reproducibility. |
| Impurity Content | Gas Chromatography-Mass Spectrometry (GC-MS) | GC separation followed by mass spectrometry for qualitative and quantitative analysis. Enables identification of unknown impurities' structures, particularly useful for trace by-products or degradation products. |
| Water Content | Karl Fischer Titration | Electrochemical titration based on the reaction between iodine and sulfur dioxide in a pyridine/methanol system with water. Provides accurate measurement of trace moisture content in samples. |
| Appearance and Color | Visual Comparison / Colorimeter | Visual inspection under standard lighting conditions or measurement using a colorimeter to assess sample color, ensuring compliance with the specification of colorless to pale yellow liquid. |
| Density | Density Meter Method (Specific Gravity Bottle or Digital Density Meter) | Measurement of sample density at a specified temperature (e.g., 20°C) using precision densimeters or specific gravity bottles, used for identification and quality consistency control. |
| Refractive Index | Abe Refractometer Method | Determination of refractive index at a specific wavelength (typically sodium D line, 589.3 nm) and temperature, serving as a physical constant to assist in authenticity verification and purity assessment. |
| Melting Point/Freezing Point | Capillary Melting Point Apparatus Method | Measurement of freezing point (more practical for liquids at room temperature) to evaluate crystallization behavior and purity (impurities lower the freezing point). |
| Residual Solvents | Headspace Gas Chromatography (HS-GC) | Sample placed in sealed headspace vials and heated to equilibrium; the gaseous phase is then analyzed by GC. Ideal for detecting volatile organic residual solvents such as toluene and ethyl acetate. |
| Heavy Metal Content | Atomic Absorption Spectroscopy (AAS) or ICP-MS | After sample digestion, determination of harmful heavy metals (e.g., lead, arsenic, mercury, cadmium) to ensure compliance with pharmacopeial or environmental regulatory limits. |
| pH Value (Aqueous Extract) | pH Meter Measurement | Sample mixed with water, shaken, and allowed to separate; the aqueous phase is measured using a calibrated pH meter to assess potential contamination by acidic or basic impurities. |
| Test Item | Specification |
|---|---|
| Appearance | Pale-yellow solid |
| Purity | >=98.0% (GC-MS) |
| Total Impurities | <=2.0% |
| Single Impurity | <=0.5% |
| Water Content (KF) | <=0.5% |
| Melting Point | 47–49°C |
| Identification (NMR) | Consistent with structure |
| Identification (IR) | Consistent with structure |
|
|
|
| CAS/Product ID | *Required fields | |
| Lot/Batch Number | *Required fields | |
1. How do you ensure product quality consistency?
We rely on a mature China-based manufacturing system and implement strict batch control and quality inspection for every shipment. Our production process complies with ISO 9001 standards, and a COA is provided for each batch to ensure consistent and reliable quality.
2. Do you offer competitive pricing for bulk orders?
Yes, as a China-based manufacturer and bulk supplier, we provide tiered pricing based on order volume. We support FOB and CIF quotations, as well as L/C payment terms for large transactions to meet international trade requirements.
3. Can you support large-volume or long-term supply?
We have stable production capacity and a well-established supply chain, enabling continuous bulk supply. We support ton-level and container-level orders, as well as long-term cooperation projects.
4. What is your typical lead time?
For in-stock products, shipment can be arranged within 1–3 days. For bulk packaging or customized orders, lead time depends on the specific quantity and production schedule.
5. What documents do you provide?
We can provide complete documentation upon request, including COA, SDS, TDS, and other compliance certificates, meeting industrial procurement and export requirements.
6. Can you customize product specifications or packaging?
Yes, we support customization of parameters such as purity, impurities, residual solvents, and heavy metals. We also offer various bulk packaging options, including 25kg bags, drums, and IBC tanks, suitable for industrial applications and transportation.
7. What shipping options do you support?
We support both FCL (Full Container Load) and LCL (Less than Container Load) shipments, and can flexibly arrange logistics solutions based on order size to meet bulk chemical export needs.
8. Do you provide technical or application support?
Yes, we provide basic application guidance and technical support based on industry experience to help customers optimize product usage.
9. How do you handle compliance and export regulations?
We are familiar with international trade and export regulations, ensuring all products comply with relevant requirements. We also provide complete documentation to support smooth customs clearance and global delivery.