China Factory Direct
|
|
| CAS number | 581-96-4 |
| Product name | 2-Naphthylacetic acid |
| Stock | Stock readily available; annual supply capacity exceeding 1,000 tons. |
| Grade | Agricultural GradeMaterial GradeSpecialty GradeReagent Grade |
| Packaging | 25KG/bag500KG/bag1000KG/bag |
| Sample | Test Samples Available (Click to Request Samples) |
| COA | View COA |
| Price | Get Quote |
| Supply Type | Bulk / Contract manufacturing / OEM |
| Shipping | FCL / LCL available |
| Payment Terms | Support FOB \ CIF \ EXW quotations, and accept Letter of Credit (L/C). |
| Manufacturer | Greenrock Chemical(China Factory) |
Based on current marketvolatility and material availability.
17+ years in chemical exports.Fully compliant, reliable supply.Your B2B partner in bulk chemical procurement.
| Industry | Application | Process |
|---|---|---|
| Agriculture | Plant growth regulator | Applied to promote root development, flower and fruit retention; typically administered via foliar spray or root dip |
| Horticulture | Rooting agent | Used to accelerate root formation during cutting propagation; commonly applied by immersing cuttings in a prepared solution |
| Forestry | Seedling root promotion | Employed in forest seedling production to improve survival rates; applied via soil drench or root treatment |
| Chemical industry | Organic synthesis intermediate | Serves as a raw material for synthesizing other naphthalene-based compounds; participates in esterification, substitution, and related reactions |
| Research | Laboratory reagent | Used in plant physiological studies to mimic auxin activity; handled in the laboratory with precise weighing and solution preparation |
| Test Item | Common Testing Method | Method Overview |
|---|---|---|
| Assay | High-Performance Liquid Chromatography (HPLC) | Uses a reversed-phase C18 column with methanol-water or acetonitrile-water as the mobile phase. Detection is performed using a UV detector (typically at 230–280 nm). The content of 2-naphthoxyacetic acid is quantified by external or internal standard methods, offering high sensitivity, excellent separation, and good reproducibility. |
| Purity Analysis | Gas Chromatography-Mass Spectrometry (GC-MS) | After derivatization (e.g., esterification), the sample is injected and separated by gas chromatography, followed by qualitative and semi-quantitative analysis using mass spectrometry. This method effectively identifies impurities and degradation products, suitable for trace-level impurity detection. |
| Structural Confirmation | Infrared Spectroscopy (IR) | Determines the infrared absorption spectrum of the sample and compares it with reference spectra to confirm the presence of functional groups (e.g., carboxyl, aromatic ring), used for preliminary structural verification. |
| Crystal Form and Physical Appearance | Differential Scanning Calorimetry (DSC) | Measures thermal changes of the sample during programmed heating to obtain information on melting point, crystallinity, etc., used to evaluate consistency of crystal form and thermal stability. |
| Moisture Content | Karl Fischer Titration | Quantifies water content in the sample based on an electrochemical reaction. Available in volumetric and coulometric modes, this method is suitable for trace moisture determination and provides accurate, reliable results. |
| Related Substances (Impurities) | High-Performance Liquid Chromatography (HPLC) | Employs gradient elution to separate the main component from potential synthesis intermediates, by-products, or degradation products. Impurity levels are calculated using peak area normalization or reference substance methods. |
| Melting Point Determination | Capillary Melting Point Method | The sample is packed into a capillary tube and heated in a melting point apparatus; the initial and final melting temperatures are observed. Used for identification and preliminary purity assessment—pure substances typically exhibit sharp melting points. |
| Heavy Metal Residues | Atomic Absorption Spectroscopy (AAS) or Inductively Coupled Plasma Mass Spectrometry (ICP-MS) | Following wet digestion, residual levels of heavy metal elements such as lead, arsenic, cadmium, and mercury are measured, ensuring compliance with pharmacopoeial or pesticide residue limits. |
| Residual Solvents | Gas Chromatography (GC) | Using headspace or direct solution injection, this method detects organic solvents remaining from manufacturing processes (e.g., methanol, acetone, dichloromethane), ensuring compliance with ICH guidelines or relevant regulatory limits. |
| Test Item | Specification |
|---|---|
| Appearance | White crystalline solid |
| Purity | >=98.0% (by LC-MS) |
| Melting Point | 133-136°C |
| Water Content (KF) | <=0.5% |
| Total Impurities | <=2.0% |
| Single Impurity | <=0.5% |
| Heavy Metals | <=10 ppm |
| Residue on Ignition | <=0.1% |
| Odor | Characteristic faint odor |
|
|
|
| CAS/Product ID | *Required fields | |
| Lot/Batch Number | *Required fields | |
1. How do you ensure product quality consistency?
We rely on a mature China-based manufacturing system and implement strict batch control and quality inspection for every shipment. Our production process complies with ISO 9001 standards, and a COA is provided for each batch to ensure consistent and reliable quality.
2. Do you offer competitive pricing for bulk orders?
Yes, as a China-based manufacturer and bulk supplier, we provide tiered pricing based on order volume. We support FOB and CIF quotations, as well as L/C payment terms for large transactions to meet international trade requirements.
3. Can you support large-volume or long-term supply?
We have stable production capacity and a well-established supply chain, enabling continuous bulk supply. We support ton-level and container-level orders, as well as long-term cooperation projects.
4. What is your typical lead time?
For in-stock products, shipment can be arranged within 1–3 days. For bulk packaging or customized orders, lead time depends on the specific quantity and production schedule.
5. What documents do you provide?
We can provide complete documentation upon request, including COA, SDS, TDS, and other compliance certificates, meeting industrial procurement and export requirements.
6. Can you customize product specifications or packaging?
Yes, we support customization of parameters such as purity, impurities, residual solvents, and heavy metals. We also offer various bulk packaging options, including 25kg bags, drums, and IBC tanks, suitable for industrial applications and transportation.
7. What shipping options do you support?
We support both FCL (Full Container Load) and LCL (Less than Container Load) shipments, and can flexibly arrange logistics solutions based on order size to meet bulk chemical export needs.
8. Do you provide technical or application support?
Yes, we provide basic application guidance and technical support based on industry experience to help customers optimize product usage.
9. How do you handle compliance and export regulations?
We are familiar with international trade and export regulations, ensuring all products comply with relevant requirements. We also provide complete documentation to support smooth customs clearance and global delivery.