HEPES Bulk Supply for Industrial Use

China Factory Direct
CAS number 7365-45-9
Product name HEPES
Stock Stock readily available; annual supply capacity exceeding 1,000 tons.
Grade Pharmaceutical GradeCosmetic GradeFood Grade
Packaging 25KG/bag500KG/bag1000KG/bag
Sample Test Samples Available (Click to Request Samples)
COA View COA
Price Get Quote
Supply Type Bulk / Contract manufacturing / OEM
Shipping FCL / LCL available
Payment Terms Support FOB \ CIF \ EXW quotations, and accept Letter of Credit (L/C).
Manufacturer Greenrock Chemical(China Factory)
Ordering Procedure & Service Assurance
Inquiry
Inquiry
Submit requirements
Quotation
Quotation
Clear pricing
Spec
Spec Confirmation
Avoid mismatch
Sample
Sample Testing
Verify quality
Order
Order
Secure deal
Delivery
Delivery
On-time
Spec Confirmation
Sample Testing
Contract Protection
QC Inspection
On-time Delivery

QUOTE TYPE

FOB (Free On Board)
CIF (Cost, Insurance, Freight)
EXW (Ex Works)

PACKAGING TYPE

TOTAL QUANTITY(KG)

PREFERRED SHIPPING METHOD

Air Freight
Sea Freight

YOUR COMPANY

YOUR E-MAIL

Calculate Summary

Based on current marketvolatility and material availability.

CAS No:7365-45-9
QUOTE TYPE:--
PACKAGING TYPE:--
TOTAL QUANTITY:--
SHIPPING METHOD:--

Documents We Provide for HEPES

COA TDS SDS NMR MOA Certificate of Origin Transport Report TSCA Declaration Production Flow Chart
Pre-sale: Only COA, SDS and NMR are available.
Post-sale: Full documentation is provided.
To request documents, please contact us via email at sales@GRchemical.com.
Bulk HEPES Supplier from China

17+ years in chemical exports.Fully compliant, reliable supply.Your B2B partner in bulk chemical procurement.

Industrial Applications of HEPES

Industry Application Process
Biopharmaceuticals Used as a biological buffer in cell culture, enzymatic reactions, and protein purification Maintains stable buffering capacity within pH 6.8–8.2; commonly applied in in vitro diagnostic reagents and biological assay systems
In Vitro Diagnostics Employed in clinical test kits to stabilize pH and ensure assay accuracy Formulated as a component of HEPES buffer for immunoassays, clinical chemistry assays, and blood analysis systems
Pharmaceutical R&D Utilized for drug solubilization, stability testing, and formulation development Applied as a non-ionic buffer to enhance aqueous solubility and chemical stability of drug molecules
Medical Devices Used for pH adjustment in certain extracorporeal circulation and dialysis solutions Combined with saline or electrolyte solutions to maintain hemocompatible conditions
Personal Care Applied as a pH adjuster in skin care products Maintains skin compatibility in mild acidic to neutral formulations, improving product stability

Manufacturing Quality Control of HEPES

Test Item Common Testing Method Method Overview
Appearance Visual Inspection Take an appropriate amount of sample and place it on a white background. Observe its color and appearance under natural light or standard light sources. It should appear as a white to off-white crystalline powder.
Identification Infrared Spectroscopy (IR) Prepare a KBr pellet of the sample and measure its infrared absorption spectrum. Compare it with the reference spectrum of the standard substance. The main absorption peak positions should be consistent.
Identification Nuclear Magnetic Resonance Hydrogen Spectroscopy (¹H NMR) Dissolve the sample in deuterated water (D₂O) or another suitable deuterated solvent, and measure the ¹H NMR spectrum. The characteristic chemical shift should match the standard spectrum.
pH Value pH Meter Method Prepare a solution of a certain concentration (e.g., 1% w/v) in water. Measure the pH value using a calibrated pH meter at a specified temperature (usually 25°C). The pH value should fall within the specified range (e.g., 2.8–3.2).
Content Determination HPLC (High-Performance Liquid Chromatography) Use a reverse-phase C18 column with a mobile phase consisting of phosphate buffer-ethanol, etc. Detect using a UV detector (e.g., 210 nm). Calculate the content of the main component using the external standard method, typically requiring ≥99.0%.
Content Determination Acid-Base Titration Dissolve the sample in water and titrate with a standard sodium hydroxide solution. Determine the endpoint using potentiometry or an indicator. Calculate the HEPES content. This method is suitable for rough quantification when there are no interfering impurities.
Dry Loss Thermogravimetric Analysis (TGA) or Atmospheric Drying Dry the sample at 105°C until constant weight is reached. Calculate the moisture and volatile matter content based on the difference in mass before and after drying. Typically, this should be ≤0.5%.
Residual Ash High-Temperature Incineration Char the sample and incinerate it in a high-temperature furnace (700–800°C) until constant weight is achieved. Weigh the residual inorganic matter and calculate its mass. Typically, this should be ≤0.1%.
Heavy Metals Thioacetamide Method (or ICP-MS) Follow the pharmacopoeia method to process the sample, add thioacetamide for coloring, and determine by colorimetry. Alternatively, use Inductively Coupled Plasma Mass Spectrometry (ICP-MS) for trace metal element quantification. Total heavy metals are usually required to be ≤10 ppm.
Chlorides Silver Nitrate Turbidimetry Acidify the sample solution with nitric acid and add silver nitrate. Compare the turbidity with that produced by a standard sodium chloride solution to control the level of chloride impurities.
Sulfates Barium Chloride Turbidimetry Acidify the sample solution with hydrochloric acid and add barium chloride. Compare the turbidity with that produced by a standard potassium sulfate solution to control sulfate impurities.
Related Substances (Impurities) HPLC (High-Performance Liquid Chromatography) Use gradient elution or isocratic conditions to separate and detect potential organic impurities (such as synthetic intermediates or degradation products). Individual impurities should typically be ≤0.1%, and total impurities ≤0.5%.
Moisture Karl Fischer Titration Determine the moisture content in the sample using either the volumetric or coulometric Karl Fischer reagent. This method provides precise measurement of water content, typically requiring ≤0.5%.

Technical Specifications of HEPES

Test Item Specification
Appearance White crystal powder
Assay 99.0% ~ 101.0%
Loss on drying ≤1.0%
pH(1% water solution) 5.0 ~ 6.5
Heavy metals as pb ≤10 ppm
UV absorbance 260nm (1M water solution) ≤0.1
UV absorbance 280nm (1M water solution) ≤0.07
Specifications vary by industry. Reach out to our technical experts for a COA tailored specifically to your application. Email:selse@GRchemical.com

Download COA of HEPES

CAS/Product ID *Required fields
Lot/Batch Number *Required fields

NMR Spectra of HEPES

Safety Information of HEPES

Pictograms
Signal Word Warning
Safety Data Sheet

Packaging of HEPES

We have a diverse range of chemicals in stock. Available in Bagged goods (25 kg.),Big bags (500 kg.), Big bags (1000 kg.).

Industrial HEPES Procurement FAQ

1. How do you ensure product quality consistency?
We rely on a mature China-based manufacturing system and implement strict batch control and quality inspection for every shipment. Our production process complies with ISO 9001 standards, and a COA is provided for each batch to ensure consistent and reliable quality.

2. Do you offer competitive pricing for bulk orders?
Yes, as a China-based manufacturer and bulk supplier, we provide tiered pricing based on order volume. We support FOB and CIF quotations, as well as L/C payment terms for large transactions to meet international trade requirements.

3. Can you support large-volume or long-term supply?
We have stable production capacity and a well-established supply chain, enabling continuous bulk supply. We support ton-level and container-level orders, as well as long-term cooperation projects.

4. What is your typical lead time?
For in-stock products, shipment can be arranged within 1–3 days. For bulk packaging or customized orders, lead time depends on the specific quantity and production schedule.

5. What documents do you provide?
We can provide complete documentation upon request, including COA, SDS, TDS, and other compliance certificates, meeting industrial procurement and export requirements.

6. Can you customize product specifications or packaging?
Yes, we support customization of parameters such as purity, impurities, residual solvents, and heavy metals. We also offer various bulk packaging options, including 25kg bags, drums, and IBC tanks, suitable for industrial applications and transportation.

7. What shipping options do you support?
We support both FCL (Full Container Load) and LCL (Less than Container Load) shipments, and can flexibly arrange logistics solutions based on order size to meet bulk chemical export needs.

8. Do you provide technical or application support?
Yes, we provide basic application guidance and technical support based on industry experience to help customers optimize product usage.

9. How do you handle compliance and export regulations?
We are familiar with international trade and export regulations, ensuring all products comply with relevant requirements. We also provide complete documentation to support smooth customs clearance and global delivery.