China Factory Direct
|
|
| CAS number | 7415-69-2 |
| Product name | Guanosine-5'-diphosphate disodium salt |
| Stock | Stock readily available; annual supply capacity exceeding 1,000 tons. |
| Grade | Pharmaceutical GradeFood Grade |
| Packaging | 25KG/bag |
| Sample | Test Samples Available (Click to Request Samples) |
| COA | View COA |
| Price | Get Quote |
| Supply Type | Bulk / Contract manufacturing / OEM |
| Shipping | FCL / LCL available |
| Payment Terms | Support FOB \ CIF \ EXW quotations, and accept Letter of Credit (L/C). |
| Manufacturer | Greenrock Chemical(China Factory) |
Based on current marketvolatility and material availability.
17+ years in chemical exports.Fully compliant, reliable supply.Your B2B partner in bulk chemical procurement.
| Industry | Application | Process |
|---|---|---|
| Biobiochemical Research | Nucleotide Metabolism Studies | Enzymatic Reactions, Biochemical Analysis |
| Pharmaceutical Industry | Drug Synthesis Intermediate | Chemical Synthesis, Modification Reactions |
| Molecular Biology | RNA Synthesis and Labeling | Solid-Phase Synthesis, Enzyme-Catalyzed Reactions |
| Food Industry | Nutritional Fortificant or Additive | Blending, Dissolution, Stabilization |
| Diagnostics Reagents | Component of Nucleic Acid Detection Kits | Labeling, Signal Amplification Processes |
| Test Item | Common Testing Methods | Method Overview |
|---|---|---|
| Appearance and Physical Characteristics | Visual Inspection + Physical Property Determination | Observe sample as white or off-white crystalline powder, free from visible foreign matter; determine solubility (freely soluble in water, insoluble in ethanol) |
| Identification Test | UV-Visible Spectrophotometry (UV-Vis) | Exhibits characteristic absorption peak near 248 nm; confirm structural features by comparing absorption spectra with reference standard. Thin-layer chromatography (TLC) may also be used to identify by comparing Rf values with reference substance. |
| Identification Test | High-Performance Liquid Chromatography (HPLC) | Use C18 column with buffer-methanol mobile phase; confirm active ingredient by comparing retention time with reference standard |
| Assay (Content Determination) | High-Performance Liquid Chromatography (HPLC) | Quantify GDP-Na₂ content using external or internal standard method with UV detection at 248 nm; meet pharmacopoeial requirements (e.g., ≥98.0%) |
| Related Substances (Impurities) | High-Performance Liquid Chromatography (HPLC) | Use gradient elution to detect potential impurities such as GMP, GTP, guanine, etc.; calculate percentage of impurity peak areas, which must not exceed specified limits (e.g., ≤1.0%) |
| Moisture Content | Karl Fischer Titration | Accurately determine moisture content and control within specified range (e.g., ≤5.0%) to ensure stability and solubility |
| Solution Clarity and Color | Visible Colorimetry / Spectrophotometry | Prepare solution at specified concentration; assess clarity and color visually or by measuring absorbance at 500–600 nm using spectrophotometer to confirm clear and colorless appearance |
| pH Value | pH Meter Measurement | Prepare 1% aqueous solution and measure pH using calibrated pH meter; maintain pH within specified range (typically 6.0–8.0) for chemical stability |
| Heavy Metals | Atomic Absorption Spectroscopy (AAS) or ICP-MS | Process sample according to pharmacopoeial method; determine levels of heavy metals such as lead, arsenic, cadmium, mercury; ensure concentrations are below permissible limits (e.g., ≤10 ppm) |
| Sulfate | Turbidimetric Method (Chinese Pharmacopoeia Method) | Add barium chloride to form barium sulfate precipitate; compare turbidity with standard sulfate solution to control sulfate content within acceptable limits |
| Chloride | Silver Nitrate Titration / Turbidimetric Method | Add silver nitrate reagent to form silver chloride precipitate; compare turbidity with standard chloride solution to control chloride content within limit (e.g., ≤0.1%) |
| Microbial Limits | Plate Count Method / MPN Method | Test for total aerobic microbial count, molds and yeasts, and presence of Escherichia coli; comply with microbial limits for non-sterile pharmaceuticals |
| Pyrogen or Bacterial Endotoxins | Limulus Amebocyte Lysate Test (LAL Test) | If used as raw material for injectables, test bacterial endotoxin level; typical limit ≤0.25 EU/mg (depending on route of administration) |
| Purity (¹H-NMR) | Nuclear Magnetic Resonance Spectroscopy (NMR) | Used for high-precision structural confirmation; verify chemical purity and structural integrity through integration ratios of characteristic proton signals (e.g., H-8, H-2, sugar ring protons) |
| Test Item | Specification |
|---|---|
| Appearance | White to off-white crystalline powder |
| Purity | >=98.5% |
| Water Content (KF) | <=0.5% |
| Total Impurities | <=1.5% |
| Single Impurity | <=0.5% |
| Heavy Metals | <=20 ppm |
| Residue on Ignition | <=0.2% |
| Optical Rotation | -15.0° to -19.0° (c=1, H2O) |
|
|
|
| CAS/Product ID | *Required fields | |
| Lot/Batch Number | *Required fields | |
| Pictograms | ![]() |
| Signal Word | Warning |
| Safety Data Sheet | |
1. How do you ensure product quality consistency?
We rely on a mature China-based manufacturing system and implement strict batch control and quality inspection for every shipment. Our production process complies with ISO 9001 standards, and a COA is provided for each batch to ensure consistent and reliable quality.
2. Do you offer competitive pricing for bulk orders?
Yes, as a China-based manufacturer and bulk supplier, we provide tiered pricing based on order volume. We support FOB and CIF quotations, as well as L/C payment terms for large transactions to meet international trade requirements.
3. Can you support large-volume or long-term supply?
We have stable production capacity and a well-established supply chain, enabling continuous bulk supply. We support ton-level and container-level orders, as well as long-term cooperation projects.
4. What is your typical lead time?
For in-stock products, shipment can be arranged within 1–3 days. For bulk packaging or customized orders, lead time depends on the specific quantity and production schedule.
5. What documents do you provide?
We can provide complete documentation upon request, including COA, SDS, TDS, and other compliance certificates, meeting industrial procurement and export requirements.
6. Can you customize product specifications or packaging?
Yes, we support customization of parameters such as purity, impurities, residual solvents, and heavy metals. We also offer various bulk packaging options, including 25kg bags, drums, and IBC tanks, suitable for industrial applications and transportation.
7. What shipping options do you support?
We support both FCL (Full Container Load) and LCL (Less than Container Load) shipments, and can flexibly arrange logistics solutions based on order size to meet bulk chemical export needs.
8. Do you provide technical or application support?
Yes, we provide basic application guidance and technical support based on industry experience to help customers optimize product usage.
9. How do you handle compliance and export regulations?
We are familiar with international trade and export regulations, ensuring all products comply with relevant requirements. We also provide complete documentation to support smooth customs clearance and global delivery.