Fmoc-L-4-Iodophenylalanine Bulk Supply for Industrial Use

China Factory Direct
CAS number 82565-68-2
Product name Fmoc-L-4-Iodophenylalanine
Stock Stock readily available; annual supply capacity exceeding 1,000 tons.
Grade Industrial Grade
Packaging 25KG/bag
Sample Test Samples Available (Click to Request Samples)
COA View COA
Price Get Quote
Supply Type Bulk / Contract manufacturing / OEM
Shipping FCL / LCL available
Payment Terms Support FOB \ CIF \ EXW quotations, and accept Letter of Credit (L/C).
Manufacturer Greenrock Chemical(China Factory)
Ordering Procedure & Service Assurance
Inquiry
Inquiry
Submit requirements
Quotation
Quotation
Clear pricing
Spec
Spec Confirmation
Avoid mismatch
Sample
Sample Testing
Verify quality
Order
Order
Secure deal
Delivery
Delivery
On-time
Spec Confirmation
Sample Testing
Contract Protection
QC Inspection
On-time Delivery

QUOTE TYPE

FOB (Free On Board)
CIF (Cost, Insurance, Freight)
EXW (Ex Works)

PACKAGING TYPE

TOTAL QUANTITY(KG)

PREFERRED SHIPPING METHOD

Air Freight
Sea Freight

YOUR COMPANY

YOUR E-MAIL

Calculate Summary

Based on current marketvolatility and material availability.

CAS No:82565-68-2
QUOTE TYPE:--
PACKAGING TYPE:--
TOTAL QUANTITY:--
SHIPPING METHOD:--

Documents We Provide for Fmoc-L-4-Iodophenylalanine

COA TDS SDS NMR MOA Certificate of Origin Transport Report TSCA Declaration Production Flow Chart
Pre-sale: Only COA, SDS and NMR are available.
Post-sale: Full documentation is provided.
To request documents, please contact us via email at sales@GRchemical.com.
Bulk Fmoc-L-4-Iodophenylalanine Supplier from China

17+ years in chemical exports.Fully compliant, reliable supply.Your B2B partner in bulk chemical procurement.

Industrial Applications of Fmoc-L-4-Iodophenylalanine

Industry Application Process
Pharmaceutical R&D Raw material for solid-phase peptide synthesis (SPPS) Coupled with standard Fmoc-amino acids to incorporate L-4-iodophenylalanine residues
Chemical Synthesis Intermediate for palladium-catalyzed cross-coupling reactions Subjected to Sonogashira or Suzuki coupling, leveraging the high reactivity of the aryl iodide moiety
Biochemistry Building block for constructing peptide libraries containing non-canonical amino acids Employed in site-directed mutagenesis or non-canonical amino acid incorporation to investigate structure–activity relationships
Chemical Synthesis Precursor for radiolabeled drugs or probes incorporating radioactive iodine Functionalized via isotopic exchange or derivatization at the iodine substitution site

Manufacturing Quality Control of Fmoc-L-4-Iodophenylalanine

Detection Item Common Analytical Method Method Overview
Assay (Purity) HPLC-UV Quantification based on peak area comparison against a certified reference standard using reversed-phase chromatography and UV detection at 260-280 nm.
Identity FTIR Spectroscopy Verification by matching characteristic functional group absorption bands (e.g., amide I/II, aromatic C-H, C-I stretch) to a reference spectrum.
Chiral Purity Chiral HPLC Separation of enantiomers on a chiral stationary phase; L-isomer content determined by relative peak area versus racemic or D-isomer reference.
Residual Solvents GC-FID Qualitative and quantitative analysis of volatile organic solvents (e.g., DMF, DCM, MeOH) using flame ionization detection after headspace or direct injection.
Water Content Karl Fischer Titration Volumetric or coulometric titration based on the stoichiometric reaction of iodine with water in a pyridine/methanol buffer system.
Heavy Metals ICP-OES Multi-element quantification of toxic metals (e.g., Pb, Cd, Hg, Ni) after acid digestion, based on element-specific atomic emission intensities.
Residual Palladium ICP-MS Ultra-trace quantification of Pd catalyst residues using mass spectrometric detection following microwave-assisted acid digestion.
Optical Rotation [alpha]D Measurement Determination of specific rotation at 589 nm using a polarimeter; confirms chiral integrity and batch-to-batch consistency.
Particle Size Distribution Laser Diffraction Analysis of dry or wet dispersed sample via light scattering pattern to derive D10, D50, D90 values.
pH (1% w/v aqueous suspension) pH Meter Measurement of hydrogen ion activity in a standardized aqueous suspension using calibrated glass electrode.
Microbial Limits Membrane Filtration Enumeration of aerobic mesophilic microorganisms and detection of specified pathogens (e.g., E. coli, S. aureus) per pharmacopeial guidelines.
Related Substances HPLC-UV Detection and quantification of structurally related impurities (e.g., deiodinated analog, diketopiperazine, Fmoc-Gly-OH) using gradient reversed-phase chromatography.

Technical Specifications of Fmoc-L-4-Iodophenylalanine

Test Item Specification
Appearance White solid
Purity >=98.5% (by LC-MS)
Total Impurities <=1.5%
Single Impurity <=0.5%
Water Content (KF) <=0.5%
Melting Point 148–152°C
Optical Rotation -11.0 to -9.0° (c=1, in DMF)
Identification (NMR) Conforms to reference spectrum
Specifications vary by industry. Reach out to our technical experts for a COA tailored specifically to your application. Email:selse@GRchemical.com

Download COA of Fmoc-L-4-Iodophenylalanine

CAS/Product ID *Required fields
Lot/Batch Number *Required fields

NMR Spectra of Fmoc-L-4-Iodophenylalanine

Safety Information of Fmoc-L-4-Iodophenylalanine

Pictograms
Signal Word Warning
Safety Data Sheet

Packaging of Fmoc-L-4-Iodophenylalanine

We have a diverse range of chemicals in stock. Available in Bagged goods (25 kg.),Big bags (500 kg.), Big bags (1000 kg.).

Industrial Fmoc-L-4-Iodophenylalanine Procurement FAQ

1. How do you ensure product quality consistency?
We rely on a mature China-based manufacturing system and implement strict batch control and quality inspection for every shipment. Our production process complies with ISO 9001 standards, and a COA is provided for each batch to ensure consistent and reliable quality.

2. Do you offer competitive pricing for bulk orders?
Yes, as a China-based manufacturer and bulk supplier, we provide tiered pricing based on order volume. We support FOB and CIF quotations, as well as L/C payment terms for large transactions to meet international trade requirements.

3. Can you support large-volume or long-term supply?
We have stable production capacity and a well-established supply chain, enabling continuous bulk supply. We support ton-level and container-level orders, as well as long-term cooperation projects.

4. What is your typical lead time?
For in-stock products, shipment can be arranged within 1–3 days. For bulk packaging or customized orders, lead time depends on the specific quantity and production schedule.

5. What documents do you provide?
We can provide complete documentation upon request, including COA, SDS, TDS, and other compliance certificates, meeting industrial procurement and export requirements.

6. Can you customize product specifications or packaging?
Yes, we support customization of parameters such as purity, impurities, residual solvents, and heavy metals. We also offer various bulk packaging options, including 25kg bags, drums, and IBC tanks, suitable for industrial applications and transportation.

7. What shipping options do you support?
We support both FCL (Full Container Load) and LCL (Less than Container Load) shipments, and can flexibly arrange logistics solutions based on order size to meet bulk chemical export needs.

8. Do you provide technical or application support?
Yes, we provide basic application guidance and technical support based on industry experience to help customers optimize product usage.

9. How do you handle compliance and export regulations?
We are familiar with international trade and export regulations, ensuring all products comply with relevant requirements. We also provide complete documentation to support smooth customs clearance and global delivery.

Industrial
Use
Bulk
Supply
Factory
Direct
ISO 9001
Certified
Samples
Available
Stable
Supply